Relé SSR-100DD [Línea SQ]

ATTENTION! Experience shows that these relays have a higher failure rate, but so far they have not been in continuous operation right from the time of commissioning (Test phase so far approx. 1 year)! Robust semiconductor relay for direct current loads with load voltages between 1…100 volts DC, max. 100A (nominal current – note discounts). Input voltage 4-32VDC. With transparent contact protection cap to ensure compliance with the minimum protection class when used in control cabinet construction IP20. Switching status display via LED when the load is switched. PUK design. Fastening via two holes on a flat, heat-dissipating mounting plate.

ATTENTION! Experience shows that these relays have a higher failure rate, but so far they have not been in continuous operation right from the time of commissioning (Test phase so far approx. 1 year)! Robust semiconductor relay for direct current loads with load voltages between 1…100 volts DC, max. 100A (nominal current – note discounts). Input voltage 4-32VDC. With transparent contact protection cap to ensure compliance with the minimum protection class when used in control cabinet construction IP20. Switching status display via LED when the load is switched. PUK design. Fastening via two holes on a flat, heat-dissipating mounting plate.

Especificación técnica

Dimensiones Dimensiones exteriores aprox. 60x48x34mm incluyendo protección de contacto.
Tipo de circuito Circuito de tiristores sin contacto para altas frecuencias de conmutación. ¡Sin desgaste mecánico!
Cargas de conmutación Carga nominal 100A. Se deben tener en cuenta las deducciones habituales por SSR al calcular la carga real conectada.
Rango de voltaje de entrada 4-32 VCC
Rango de voltaje de carga 1 …100 VCC
Clase de protección IP 20
Asamblea Sobre una superficie plana y disipadora de calor (placa de montaje para armario eléctrico) utilizando dos orificios existentes, diámetro aprox. 4,5 mm. Distancia entre los agujeros aprox. 43 mm, dispuestos centralmente.

Application

When designing switching loads, the usual discount factors for SSR relays from the specified nominal load must be taken into account. So are e.g. B. for switching inductive loads (e.g. motors) when using SSR relays, often only 1/8 of the specified nominal load of the SSR has to be taken into account for operation with motors. For ohmic loads, the actual load can usually be up to 20% of the specified nominal load. With medium to high loads and ED >20% (ED = duty cycle), the use of a heat sink to dissipate thermal energy is necessary. As a preventive measure, we generally recommend the use of suitable heat sinks.

Peso 0,200 kg